Bộ tác động điện ASAHI - Series 92 cho van bi và van bướm
Applications:
Electrically actuator options for:
3. Asahi - Butterfly valve type 57
4. Asahi - Butterfly valve type 75
5. Asahi - Butterfly valve type SP
6. Asahi - Diaphragm valve type 14
7. Asahi - Diaphragm valve type 15
Features and Benefits
- Motor: Reversing, brushless, capacitor run 115 VAC 50/60 Hz, single phase
- RoHS compliant
- UL-508 approved
- Overload protection: Integral thermal overload protection for motor windings with automatic reset
- Gear train: Permanently lubricated, solid gear that is Rockwell hardened
- Corrosion resistant housing: Thermally bonded, baked powder coating with stainless steel trim
- ISO mounting configuration
- Conduit: Two 1/2" NPT conduit entries to eliminate cross feed between control, feedback and power signals
- Position indication: Highly visible beacon position indicator for positive position of valve, even at a distance
- Declutchable manual override: Pull up on indicator knob, insert 5/8" wrench onto flats and rotate in the appropriate direction (CCW for open, CW for close). Models with handwheel override do not require a wrench. Simply push down on handwheel until engaged with cam and rotate
- Limit switches: Standard end-of-travel limit switches can be used for light indication (not to be used with PLC for position confirmation)
- Enclosure: Combination NEMA 4X, 7 and 9 enclosure for use in various environments
- Corrosion resistant mounting: Mounting is with PPG or stainless steel bracket, stainless steel coupling, and stainless steel hardware
- CE compliant motor: All 115 VAC and 230 VAC motors are CE compliant and stamped as such
- Extended duty cycles: Our extended duty cycles are ideal for modulating and high cycling applications
- Output torque: Series 92 Electric Actuators have an output torque range from 400 in/lbs to 2000 in/lbs
Options
- Feedback potentiometer
- Auxiliary (additional) limit switches
- Heater and thermostat
- 4-20 mA positioner (modulating PCB)
- Mechanical brake
- 4-20 output source (transmitter)
- Cycle length control module (CLC)
- Two-wire control
- Failsafe battery back up (Protek)
- Voltages
- Local remote station
Thông số kỹ thuật
Engineering Specification
- Size: S92, A92, B92 and C92
- Torque: 400-2000 in/lbs
- Voltage: 120 VAC 1Ph 50/60 Hz
- Amp Draw: S92, B92 .5A, A92 .8A, C92 1.0A
- Conduit Entry: Two 1/2" NPT
- Max Ambient Temperature:150ºF
- Switches: Two single pole, double throw (2SPDT) 15 amp rated
- Cycle Time per 90º: S92, A92: 10 seconds; B92, C92: 25 seconds